Create Moving Point Loads

Purpose

To create moving point loads (sprinklers, for example)

Steps

 

1.  Click Component to open the Component Loading window. Then click Moving Pt Load to open the Moving Point Load window.

2.  Complete the following settings on the Moving Point Load window.

Name - user-defined name/description

Load Domain - select Top Load, Bottom Load, or TandB Load (top & bottom load)

Where - select Panel Points, Mid Panel, both, or Two Ft on Center

Magnitude of Live Load - select a value from the drop down list

Magnitude of Dead Load - select a value from the drop down list

Concurrent - check the box if live and dead loads are concurrent

Dead Load Static - if the box is checked, it places the dead load amount at all locations at once, then moves the live load. If this is unchecked, both the dead load and the live load amounts are moved together as a pair.

Start (from left end) - select a value from the drop down list

End (from right end) - select a value from the drop down list

Deflection Limits - enter a value

 

3.  Click Save.

The moving point load displays in the list. You can use Copy to make a copy of the load, make edits, and save it as a new moving point load.

4.  Click OK to exit the window.

5.  On the Component Loading window, click the check box next to Moving Pt Load to apply that loading.

Related Topics

Component Loading

Create Moving Distributed Loads